4.3.3.
“Section 9.3.6 Test”
Note:
*1
: When scanning image has some lines, this operation (Focus test) will find their
locations on the image.
When this operation is executed, the figure of the scanning level will indicate,
beginning at the left of the scanning device.
This focus test shows partial depression of the level if there are some damages
(scratch or others) to the glass surface or a dust on the surface.
If there are some damages to the glass, replace it.
When this phenomenon appears (with no damage to the glass surface), clean the
surface with Roller Cleaning Paper we provide. And then if the lines still remain,
execute "Shading".
When this operation is executed, the figure of the scanning level will indicate,
beginning at the left of the scanning device.
This focus test shows partial depression of the level if there are some damages
(scratch or others) to the glass surface or a dust on the surface.
If there are some damages to the glass, replace it.
When this phenomenon appears (with no damage to the glass surface), clean the
surface with Roller Cleaning Paper we provide. And then if the lines still remain,
execute "Shading".
Item
Operation
Default
Remarks
*1
CIS Focus 1. Pull the Front Door Release to open the
Front Door.
2. Reverse the Reference Plates to white.
3. Close the Front Door slowly until it clicks
into place.
4. Click “CIS Focus” on the main menu.
5. Click “START” on the “CIS Focus” dialog
box.
6. Check the waveform indicated on the display.
7. When finishing confirming the output image
level, click “STOP” on the “CIS Focus”
dialog box.
8. Click “Close” to get back to the main menu.
9. Pull the Front Door Release to open the
Front Door, and then reverse the Reference
Plates to black.
10. Close the Front Door slowly until it clicks
into place.
2. Reverse the Reference Plates to white.
3. Close the Front Door slowly until it clicks
into place.
4. Click “CIS Focus” on the main menu.
5. Click “START” on the “CIS Focus” dialog
box.
6. Check the waveform indicated on the display.
7. When finishing confirming the output image
level, click “STOP” on the “CIS Focus”
dialog box.
8. Click “Close” to get back to the main menu.
9. Pull the Front Door Release to open the
Front Door, and then reverse the Reference
Plates to black.
10. Close the Front Door slowly until it clicks
into place.
—
This operation
indicates a focus-level
waveform to check
whether there is any
partial depression of
the level.
indicates a focus-level
waveform to check
whether there is any
partial depression of
the level.