116
3. Pixel data from Optical Unit
Front or image processing
circuit has some problems.
Front or image processing
circuit has some problems.
1. Check the following connections and
soldering condition on each connector.
a. CN5002 (CCD (F) Board) to CN1003
(CONTROL Board)
b. CN5003 (CCD (F) Board) to CN1004
(CONTROL Board)
2. Check the following power supply to
CONTROL Board.
soldering condition on each connector.
a. CN5002 (CCD (F) Board) to CN1003
(CONTROL Board)
b. CN5003 (CCD (F) Board) to CN1004
(CONTROL Board)
2. Check the following power supply to
CONTROL Board.
→ CN1004-1st pin (CONTROL Board): 12 V
→ CN1004-3rd pin (CONTROL Board): 5 V
→ CN1004-5th pin (CONTROL Board): 3.3 V
3. Check that the following signals on the
CONTROL Board are normal.
CONTROL Board are normal.
→ Test point (R0040): 30 MHz
4. Check the soldering condition of the all ICs
and their surrounding parts on the CCD (F)
Board.
5. Check the soldering condition of the
CN1004, IC0001, and their surrounding
circuit on the CONTROL Board.
6. Replace faulty parts or boards.
and their surrounding parts on the CCD (F)
Board.
5. Check the soldering condition of the
CN1004, IC0001, and their surrounding
circuit on the CONTROL Board.
6. Replace faulty parts or boards.
F61 (Front-side
black level error)
black level error)
51
00
00
00 1. Pixel data from Optical Unit
Front or image processing
circuit has some problems.
circuit has some problems.
Refer to the above 3rd item on the F60.
F62 (Back-side gain
adjustment error)
adjustment error)
52
00
00
00 1. Scanning Glass (B) is dirty.
Clean the glass surface. (See 7.2.)
2. Light Unit (B) does not work
properly.
properly.
1. Execute CCD Level test in Sec.9.3.6 to
check the peak level.
2. Check that LED (B) lights during CCD Level
test.
3. Check the following connections and
soldering condition on each connector.
a. LED (B) Board to CN4008 (DRIVE Board)
b. CN4002 (DRIVE Board) to CN1002
(CONTROL Board)
4. Check the lamp control signals to the Lamp
Driver.
check the peak level.
2. Check that LED (B) lights during CCD Level
test.
3. Check the following connections and
soldering condition on each connector.
a. LED (B) Board to CN4008 (DRIVE Board)
b. CN4002 (DRIVE Board) to CN1002
(CONTROL Board)
4. Check the lamp control signals to the Lamp
Driver.
→ IC4009-1st pin: 10 V
→ CN4002-28th pin: 0 V (when lamp is ON)
5. Replace faulty parts or boards.
3. Pixel data from Optical Unit Back
or image processing circuit
has some problems.
or image processing circuit
has some problems.
1. Check the following connections and
soldering condition on each connector.
a. CN5002 (CCD (B) Board) to CN1005
(CONTROL Board)
b. CN5003(CCD (B) Board) to CN1006
(CONTROL Board)
2. Check the following power supply to
CONTROL Board.
soldering condition on each connector.
a. CN5002 (CCD (B) Board) to CN1005
(CONTROL Board)
b. CN5003(CCD (B) Board) to CN1006
(CONTROL Board)
2. Check the following power supply to
CONTROL Board.
→ CN1006-1st pin (CONTROL Board): 12 V
→ CN1006-3rd pin (CONTROL Board): 5 V
→ CN1006-5th pin (CONTROL Board): 3.3 V
3. Check that the following signals on the
CONTROL Board are normal.
CONTROL Board are normal.
→ Test point (R0081): 30 MHz
4. Check the soldering condition of the all ICs
and their surrounding parts on the CCD (B)
Board.
5. Check the soldering condition of the
CN1006, IC0002, and their surrounding
circuit on the CONTROL Board.
6. Replace faulty parts or boards
and their surrounding parts on the CCD (B)
Board.
5. Check the soldering condition of the
CN1006, IC0002, and their surrounding
circuit on the CONTROL Board.
6. Replace faulty parts or boards