KV-S3105C, KV-S3085 (serv.man3) - Panasonic Other Service Manuals Service Manual (repair manual). Page 122

Read Panasonic KV-S3105C / KV-S3085 (serv.man3) Service Manual online

CN2001 (MOTHER) – CN1001 (CONTROL)
Pin No.
Signal Name
Description
CN2001
CN1001
1
1
GND
Ground
2
2
GND
Ground
3
3
GND
Ground
4
4
GND
Ground
5
5
*M_HWR
CPU Write Signal
6
6
*M_CS5
Chip Select 5
7
7
*M_RD
CPU Read Signal
8
8
*M_CS6
Chip Select 6
9
9
GND
Ground
10
10
GND
Ground
11
11
GND
Ground
12
12
GND
Ground
13
13
LD [7]
Local Data Bus
14
14
LD [6]
Local Data Bus
15
15
LD [5]
Local Data Bus
16
16
LD [4]
Local Data Bus
17
17
LD [3]
Local Data Bus
18
18
LD [2]
Local Data Bus
19
19
LD [1]
Local Data Bus
20
20
LD [0]
Local Data Bus
21
21
GND
Ground
22
22
GND
Ground
23
23
*IM_REQ
Request Signal from INTERFACE to CONTROL
24
24
*IM_ACK
Acknowledge Signal from CONTROL
25
25
3.3V
+3.3 V
26
26
JS_CLK
Double – Feed Detector Clock (100 kHz)
27
27
3.3V
+3.3 V
28
28
K_MVREF
Setting Current for Paper Feed Motor
29
29
3.3V
+3.3 V
30
30
K_MCLK
Paper Feed Motor’s Clock
31
31
3.3V
+3.3 V
32
32
H_MVREF
Setting Current for Conveyor Motor
33
33
GND
Ground
34
34
H_MCLK
Conveyor Motor’s Clock
35
35
GND
Ground
36
36
P_MVREF
Setting Current for Hopper Motor
37
37
GND
Ground
38
38
BUZZER
Buzzer Clock
39
39
GND
Ground
40
40
5V
+5 V
41
41
SVSYNC
V sync.
42
42
5V
+5 V
43
43
*RES_DES
Not used
44
44
5V
+5 V
45
45
GND
Ground
46
46
5V
+5 V
47
47
*RES_IF
Reset Signal
48
48
*RESET5
Reset Signal
49
49
GND
Ground
50
50
GND
Ground
51
51
*DM_REQ
Not used
52
52
*DM_ACK
Not used
53
53
CPUA [15]
MAIN CPU Address
54
54
*INT_SCSI
INTERFACE Interrupt
55
55
CPUA [14]
MAIN CPU Address
56
56
*INT_MAIN
Interrupt Signal [CONTROL to INTERFACE]
57
57
CPUA [13]
MAIN CPU Address
122
KV-S3105CSERIES / KV-S3085SERIES
Page of 127
Display