XII. METHOD TO REPAIRING REFRIGERATING UNIT
CONDITION I. NOT COLD
Compressor not run 
CONDITION II. COLD LESS
CONDITION III. VERY COLD
Both terminal direct 
joining
Compressor run
Compressor not run
Compressor run
Check with Ohm 
Meter ( Tester )
Change Thermostat
OLP broken
Check with M.Tester
Change O L P
Starting PTC broken
Check with M.Tester
Change Starting PTC
Motor winding burn
Check with M.Tester
Change Compressor
Compressor noise 
but not run
Power source broken 
(Start Voltage not 
enough )
Starting P.T.C. 
broken
Motor winding 
disconnect
Starting Motor burn
Check Starting 
P.T.C. Voltage under 
load
Check with
 M.Tester
Check with M.Tester
Repair Power Source
Change PTC Starting
Change Compressor
Change Compressor
Cooling Unit brooken
Gas leakage
Be found gas residu
Repair gas leakage 
and re-charge 
Gas nothing 
Spray with gas
Compressor run but 
not compress
Short time
Operation fault
Thermostat broken
Change Thermostat
Compressor running
Long time
Out side Evaporator
Evaporator closed by 
frost to more
Evaporator not close 
by frost
Very Cold
Touch Defrost button
Cooling Unit broken
Repair at cooling unit 
portion
Joint pipe leakage 
and clogged
The door have more 
gap
Open the door very 
long time
Cold Less
Check Cooling Unit
Repair at cooling unit 
portion
Adjust the door
Give the direction to 
customer
Censor  cappilary 
Thermostat have 
more gap
Thermostat broken
Thermostat not have 
voltage
Assembly censor 
cappilary Thermostat
Check with M.Tester
Setting end of Censor 
at center hole
Change Thermostat
Repair Thermostat 
wiring
Check with M.Tester
CHECK
CAUSE
SUSPECT
ANALYSIS
ACTION