1. TROUBLE - SHOOTING
Symptom: No cooling at all or insufficient cooling
Does compressor run ?
Check starting 
circuit
Replace faulty electric 
parts
No
No good
Check resistance of 
motor winding with 
ohm meter
Compressor locking
Check Oil Compressor
Pipe Cleaning         
                                  
Replace compressor
Motor winding 
disconnect or burn
OK
No Good
Change Thermostat
Does Thermostat good 
operation?
Check    Thermostat
No
Yes
Check frost on Evaporator
Yes
Clog caused by 
moisture
Replace faulty 
electric part
Check out weather oil is 
oozing
Little Frosting or just on Inlet tube eva only
Gas leakage
Cut capillary tube at 
outlet of dryer
Check the smell
Check compressor 
oil
Can not repair
Bad smell
Occasionally frosting
Frosting too much
Yes
Compressor broken
Check Compressor Oil
Pipe Cleaning
Replace Compressor
Clog caused by 
solid substance
Clog caused by 
solid substance
Make compressor stop and 
check if gas come out by 
cutting capillary tube ar 35 
mm from outlet of dryer
Gas come out from both dryer side 
and evaporator side
Gas come out from evaporator side only
Gas come out from dryer side only
No
(Clog near inlet of evaporator)
(Thermostat, starting relay, motor protector, starting 
capacitor, running capacitor, defrost timer)
OK
OK