Caution:
-
-
1.
2.
3.
X. TOOL FOR REPAIRING REFRIGERATING UNIT HFC-134a
When the fitting for CFC-12 use is connected with the charge pipe (yellow), and then turn
the switch to CFC-12 use, the adaptor can be used for vacuum pumping of CFC-12
refrigeratirng unit.
Be sure connect the adaptor with vacuum pump, so it that the vacuum pump can be used
for both CFC-12 and HFC-134a.
Since the inside of manifold gauge and charge hoses are vacuum state after vacuum
pumping, the oil of vacuum pumping may flow into HFC-134a refrigerant unit. The adaptor
prevents the oil from flowing into the refrigerating unit.
Before running the vacuum pump, connect the charge pipe (yellow) with the fitting for HFC-
1354a use, and then turn the switch to HFC-134a use.
Conventional repairing devices for CFC-12 can not connect with repairing devices for HFC-
134A.  Because the shape of fitting for HFC-134A (M10 x P1.5 mm) is different from 
conventional ones.
Coupler Plug ( High Pressure Side ) 4mm
Coupler Socket
Coupler Plug ( Low Pressure Side ) 6.33 / 8mm
Process-Tube-Fitting
( 6.35 mm )
Process-Tube-Fitting
( 4 mm )
Charge Adaptor
Charge Cylinder
Blue
Yellow
Adaptor
Red
Manifol Gauge
Control Valve
Charge Hose
Vacuum Pump
(for CFC-12/HFC-134a)
Fitting for Vacuum Pump
Fitting for
CFC-12
Switch 
( CFC-12 / HFC-134a )
Fitting for
 HFC-134a
-8-