NR-AF162SNAE, NR-AF162SNWG - Panasonic Home Appliance Service Manual (repair manual). Page 9

Read Panasonic NR-AF162SNAE / NR-AF162SNWG Service Manual online

XI. REFRIGERATING UNIT REPAIRING PROCEDURE
STANDARD PROCEDURE
Diagnosing the trouble
Discharging the refrigerant
Removing the Compressor
Checking the compressor oil
A little discoloration 
(light yellow)
Severe discoloration 
(light brown)
Purging the pipe At 
high-pressure side
Purging the pipe at low-
pressure side
Joining compressor 
and accumulator assy'
Setting the compressor and the dryer
Vacuum pumping and pot the electric parts
Charging the refrigerant
Leakage test
Test Run
Pinch-off seal of charge pipes
Finish
Refer to the TROUBLESHOOTING
* For purging the pipe, use HFC-134a as liquid state.
* Never use HCFC-141b, HCFC-22 for purging.
* Do not keep the pipes open to air more than 30 minutes.
These process in total should be finished within 
30 minutes.
 * Rubber caps should be removed just before 
compressor is used. Never leave the  compressor 
without the caps and open to the air.
 Be sure to connect the adaptor with vacuum     
pump.
Charge cylinder should be exclusive - use for 
HFC-134a.
This is to prevent different refrigerant                                                        
( CFC-12, HCFC-22, CFC-113, HFCFC-141b, R-
502) from mixing with  HFC-134a.
IMPORTANT THINGS
-9-