UF-6300, UF-6200, UF-5300 - Panasonic Fax Service Manual (repair manual). Page 121

Read Panasonic UF-6300 / UF-6200 / UF-5300 Service Manual online

121
438
RCV
B
Refusal ID (Junk Fax ID) received 
in Phase B.
Transmitter ID is registered as a Junk 
Fax. JUNK is printed as the Information 
Code on the Comm. Journal.
456
RCV
B
Received relay transfer request or 
confidential document to distribute 
to an end receiving station or all 
confidential mailboxes are used.
459
RCV
C
Failed training in Phase C.
Line quality is poor. (Training signal is 
distorted due to line noise)
SC PCB or MJR PCB are defective.
490
RCV
C
Sum of error lines exceeded the 
limit (Function Parameter No. 70) of 
64 lines.
Line quality is poor.
SC PCB or MJR PCB are defective.
494
RCV
C
Interval between two EOLs was 
more than 10 sec. when receiver 
received message data.
Transmitter is defective.
Line quality is poor. (EOL is damaged 
due to line noise)
SC PCB or MJR PCB are defective.
495
XMT 
RCV
C
During reception, CD turned OFF 
or continued ON for long time. 
During communication, lost loop - 
current.
Line is disconnected.
Transmitter is defective.
SC PCB or MJR PCB are defective.
496
XMT
C
CS of modem is not able to turn 
ON.
SC PCB is defective.
501
XMT/
RCV(V.34)
B
Remote unit does not have 
compatible Modem.
502
XMT/
RCV(V.34)
B, C, D During reception, CD turned OFF 
or continued ON for long time. 
During communication, lost loop - 
current.
Line is disconnected.
Transmitter is defective.
SC PCB or MJR PCB are defective.
503
XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn ON 
during training.
SC PCB is defective.
Line is disconnected.
504
XMT/V.34
(Polling)
B
Polling is rejected from the remote 
station.
No polling original is set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original is set.
540
XMT ECM
B
No response after transmitting 3rd 
CTC or DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd 
EOR or received DCN.
Line is faulty.
MJR PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR 
transmitted or received DCN.
Remote unit is abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without 
MCF.
Remote unit is abnormal.
544
XMT ECM
D
Stopped Transmission after EOR 
Transmission.
Line is faulty.
MJR PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C 
has elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving 
EOR.
Line is faulty.
555
RCV ECM
D
Transmitted PIN after receiving 
EOR.
Line is faulty and Operator Call 
requested by RX side.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Page of 127
Display

Click on the first or last page to see other UF-6300 / UF-6200 / UF-5300 service manuals if exist.