UF-490 (serv.man2) - Panasonic Fax Service Manual (repair manual). Page 121

Read Panasonic UF-490 (serv.man2) Service Manual online

121
017 TX START
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = TC7200 bps
6 = TC9600 bps
7 = 12000 bps
8 = 14400 bps
Selects the transmission modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
Note:
This parameter is applicable only when 
communicating with regular G3 machines. When 
communicating with Super G3 (V.34) machines, 
use Parameter No. 32.
018 RX START
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = TC7200 bps
6 = TC9600 bps
7 = 12000 bps
8 = 14400 bps
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
Note:
This parameter is applicable only when 
communicating with regular G3 machines. When 
communicating with Super G3 (V.34) machines, 
use Parameter No. 33.
019 ITU-T V.34
1 = Off
2 = On
3 = Select
Selects whether the ITU-T V.34 is Off, On or Select.
Select: Select whether the ITU-T V.34 is Off or On, 
when entering Phone Book Dialing Numbers 
or Manual Number Dialing.
020 ITU-T ECM
1 = Off (Invalid)
2 = On  (Valid)
Select the ECM mode.
021 EP TONE
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects whether to add the echo protect tone on V.29 
mode.
(Used when Echo Suppression is disabled.)
On : Add
Off : Do not add
022 SIGNAL 
INTERVAL
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving signal 
and the transmitting signal.
023 TCF CHECK
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
024 CED 
FREQUENCY
1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
025 COMM. START-
UP
1 = 1’st response
2 = 2’nd response
Selects the communication start-up condition (XMT 
and Polling).
(Used when Echo Suppression is disabled.)
026 NON-
STANDARD
1 = Off (Invalid)
2 = On (Valid)
Selects own mode (Panafax mode).
027 SHORT 
PROTOCOL B
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode.
028 SHORT 
PROTOCOL D
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode. When activated, it 
allows the machine to automatically store the modem 
speed for each Auto Dial Number.
029 REMOTE 
DIAGNOSTICS
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts Remote 
Diagnostics from the service station.
030 CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and the 
300 bps signal.  
(Used when Echo Suppression is disabled.)
031 RTC = EOLx12
1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
Function Parameter Table
No.
Parameter
Selections
Function
Page of 127
Display

Click on the first or last page to see other UF-490 (serv.man2) service manuals if exist.