WV-CW960, WV-CW964 - Panasonic Video Monitoring Service Manual (repair manual). Page 13

Read Panasonic WV-CW960 / WV-CW964 Service Manual online

2-7
REMOTE
OPERATE
PROG
ALARM
RESET
NORMAL
SYSTEM
ALARM OFF
EVR
Left
Switch
Right
Switch
Mode Selection
Switch
Program
Switch
Up
Switch
Down
Switch
Set
Switch
IN
OUT
STD. CAMERA
VP CAMERA
VIDEO
CAMERA
DC12V IN
RS232C
VP/STD Camera Selection Switch
RS232C Connector
3.2. Setting Up for Remote E.V.R. 
Adjustment Kit
(1) Remote E.V.R. Adjustment Kit
Fig. 3-2-1
(2) Switch Setting  
8
Referring to Fig. 3-2-2, remove four screws that secure
the Upper Cover and remove the Upper Cover.
Remove four screws.
Upper Cover
Fig. 3-2-2
8
Set the switch SW3 on the Board to the position as
shown in Fig. 3-2-3.
8
Set the VP/STD.Camera Selection Switch on the Rear
Panel to STD CAMERA position. 
(3) Menu Setting
8
Set the Mode Selection Switch on the Front Panel to the
"ALARM OFF" (center) position.
8
Keep pressing the Program Switch for 3 seconds or more
until "Program Menu" is displayed on the monitor screen.
8
Move the cursor to the "Controller Set Up" position by
pressing the Up and Down Switch.
8
Display the "Controller Set Up Menu" on the monitor by
pressing the Set Switch.
8
Move the cursor to the "Set Up Disable" position by
pressing the Up and Down Switch.
8
Change "Disable" to "Enable" by pressing the Set Switch.
8
After completing the above setting, move the cursor to
the Communication position by pressing the Up and
Down Switch.
8
Display the "Communication Menu" on the monitor by
pressing the Set Switch .
8
After confirming the Baud Rate is 9600, finish this menu
by pressing the Program Switch twice.
<Rear>
<F
ront>
Board
SW3
ON
<SW3>
<SW3>
1 2 3 4
Select switch #2 to ON (PAL) position.
#
ON
OFF
1
FIX
2
NTSC
PAL
3
FIX
4
FIX
Fig. 3-2-3
Page of 65
Display

Click on the first or last page to see other WV-CW960 / WV-CW964 service manuals if exist.