Read Panasonic WV-CW960 / WV-CW964 Service Manual online
2-6
8
Reconnect the following connectors by using the
Extension Board Ass'y (Refer to Fig. 1-2) and the
Extension Cable (Refer to Fig. 1-3) for WV-CS850 Series.
1. Connect the Extension Cable
Extension Board Ass'y (Refer to Fig. 1-2) and the
Extension Cable (Refer to Fig. 1-3) for WV-CS850 Series.
1. Connect the Extension Cable
D
(Refer to Fig. 1-2)
between CN2, CN3 on the Communication Board and
the Cables of CN2, CN3 on the Switch Board in the
Dome Housing Unit.
the Cables of CN2, CN3 on the Switch Board in the
Dome Housing Unit.
2. Connect the Extension Cable (Refer to Fig. 1-3)
between CN5 on the Communication Board and the
Cables of E5 on the Power Board in the Dome
Housing Unit.
Cables of E5 on the Power Board in the Dome
Housing Unit.
8
Reconnect the Cable of the Slip Ring to CN7 on the
Communication Board.
Communication Board.
8
Reconnect the Flexible Flat Cable between CN4 on the
Main Board and CN1 on the Servo Board.
Main Board and CN1 on the Servo Board.
8
Reconnect the Flexible Flat Cable between CN204 on the
Main Board and CN400 on the Tilt Board.
Main Board and CN400 on the Tilt Board.
8
Supply the power to the Camera.
8
Contact the magnet to VS1 on the Servo Board.
3. Connection and Setting Up for
Adjustment
3.1. Connection
8
The Fig. 3-1-1 shows the connecting diagram for the
Adjustment Procedure.
Adjustment Procedure.
Fig. 3-1-1
Test Chart
Floppy
Disk
Disk
Underscanned
Colour
Video Monitor
Colour
Video Monitor
Video
Output
Connector
Output
Connector
Remote E.V.R.
Adjustment
Kit
Standard
Straight
RS-232C
Cable
Straight
RS-232C
Cable
RS232C
DC12V
IN
IN
Personal
Computer
Computer
75
Ω
WV-CW960
WV-CW964
WV-CW964
Vectorscope
Power Cable
Power Connector
CAMERA
IN
VIDEO
OUT
24 V AC
Power Supply Unit
Power Supply Unit
(For WV-CW964)
220-240 V AC
(For WV-CW960)
220-240 V AC
(For WV-CW960)
12 V DC
Power Supply Unit
Power Supply Unit
8
Connect the Underscanned Colour Video Monitor to the
VIDEO OUT Connector of the Remote E.V.R. Adjustment
Kit through the Vectorscope by using the coaxial cables.
VIDEO OUT Connector of the Remote E.V.R. Adjustment
Kit through the Vectorscope by using the coaxial cables.
8
Connect the Video Output Connector of the WV-
CW960/WV-CW964 to the CAMERA IN Connector of the
Remote E.V.R. Adjustment Kit by using the coaxial cable.
CW960/WV-CW964 to the CAMERA IN Connector of the
Remote E.V.R. Adjustment Kit by using the coaxial cable.
8
Terminate the input terminal of the Underscanned Colour
Video monitor with 75
Video monitor with 75
Ω
.
8
Connect the 24 V AC Power Supply Unit to the Power
Connector of the WV-CW964.
Connector of the WV-CW964.
8
Connect the 12 V DC Power Supply Unit to the E.V.R.
Adjustment Kit.
Adjustment Kit.
8
Connect the Remote E.V.R. Adjustment Kit to the
Personel Computer (IBM PC/AT type) by using the
Standard Straight RS-232C cable.
Personel Computer (IBM PC/AT type) by using the
Standard Straight RS-232C cable.
8
Connect the probe of the Oscilloscope or Frequency
Counter at the desired Test Point in each adjustment
step.
Counter at the desired Test Point in each adjustment
step.
Click on the first or last page to see other WV-CW960 / WV-CW964 service manuals if exist.