< Menu Setting >
8
Set the Mode Selection Switch on the Front Panel to the
"ALARM OFF"(center) position.
8
Keep pressing the Program Switch for 3 seconds or more
until "Program Menu" is displayed on the monitor screen.
8
Move the cursor to the "Controller Set Up" position by
pressing the Up and Down Switch.
8
Display the "Controller Set Up Menu" on the monitor by
pressing the Set Switch.
8
Move the cursor to the "Set Up Disable" position by
pressing the Up and Down Switch.
8
Change "Disable" to "Enable" by pressing the Set Switch.
8
After completing the above setting, move the cursor to
the Communication position by pressing the Up and
Down Switch.
8
Display the "Communication Menu" on the monitor by
pressing the Set Switch.
8
After confirming the Baud Rate is 9600, finish this menu
by pressing the Program Switch twice.
< Installing E.V.R Adjustment Program >
8
The Example given here is for A 2 drive computer, your
procedure might vary slightly depending on the drive
configuration.
8
Confirm that the contents of CONFIG.SYS file on your
computer is DEVICE=ANSI.SYS(Basic).
8
Insert floppy disk containing E.V.R. adjustment program
into your floppy drive (for example,drive:A) and type A:
8
At the prompt, type CD IBMPC and press ENTER key.
8
Type COPY RADJ2.EXE B: and press ENTER key.
8
Type CD\ and press ENTER key.
8
Type CD SEQ and press ENTER key.
8
Type COPY CS854BE.SEQ B: and press ENTER key.
8
Type COPY CS85BEAF.SEQ B: and press ENTER key.
8
Type COPY CS85BETL.SEQ B: and press ENTER key.
8
Type COPY CS85BEPR.SEQ B: and press ENTER key.
8
Type CD\ and press ENTER key.
8
Type CD EVR and press ENTER key.
8
Type COPY CS854BE.EV2 B: and press ENTER key.
8
After completing installation of program, you are ready to
use the E.V.R. adjustment program.
3.3. Setting Up for Standard Picture
8
The adjustment should be done after 30 minutes warm-up.
8
Set the Logarithmic Gray Scale Chart.
8
Incident light of 1 400 lx ± 50 lx on the Logarithmic Gray
Scale Chart.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Set the Camera by the E.V.R. Adjustment Kit so that the
Logarithmic Gray Scale Chart becomes full picture on the
Underscanned Colour Video Monitor.
8
Adjust the Lens Focus by the E.V.R. Adjustment Kit to
obtain correct focal point.
8
The adjustments should be done with this Standard
Picture, unless otherwise specified.