4. Adjustment Procedure
4.1 Camera Adjustment
4.1.1 Starting E.V.R. Adjustment Program
8
Insert new floppy disk containing DOS Operating System
and the E.V.R. Adjustment Program into IBM PC/AT and
turn on the IBM PC/AT.
8
At the prompt, type RADJ2 CS854BE and press the
ENTER key, then the initial menu page as shown in Fig. 4-
1-1 will be displayed.
Fig. 4-1-1
4.1.2. Saving the Adjustment Data
This saving procedure is recommended to keep the current
adjustment status of the camera.
8
Press the SAVE (F5) key of the computer, and the
computer will ask you for the file name.
8
Type  xxxxxxxx.EV2 CC0 14CA. Give an appropriate file
name for xxxxxxxx within 8 letters, but do not use
CS854BE.
8
Press the ENTER key.
4.1.3. Loading the Adjustment Data
This loading procedure is recommended to return the
adjustment status of the camera to the factory default setting
or the setting you saved before.
8
Press the LOAD (F1) key of the computer, and the
computer will ask you for the file name.
8
Type CS854BE.EV2 or xxxxxxxx.EV2 (xxxxxxxx means
a file name you named before.) and press the ENTER
key.
4.1.4. Adjustment Procedure
8
Select the item "1. SC FREQUENCY" with the ARROW
key and press the ENTER key.
(1) Subcarrier Frequency Adjustment for INT mode
Test Point:
TD4 (SC VCXO)
8
Connect the Frequency Counter to TD4 as shown in Fig.
4-1-2.
Fig. 4-1-2
8
Adjust the data with the ARROW key so that the
Subcarrier Frequency becomes 17.734 47 MHz ± 40 Hz.
8
Press the ENTER key for the next adjustment.
(2) Subcarrier Frequency Adjustment for LL mode
Test Point:
TD4 (SC VCXO)
8
Connect the Frequency Counter to TD4 as shown in Fig.
4-1-2.
8
Adjust the data with the ARROW key so that the
Subcarrier Frequency becomes 17.734 47 MHz ± 40 Hz.
8
Press the ENTER key for the next adjustment.
(3) Line Lock Phase Adjustment
Test Point:
Video Output Connector
AC Live Waveform
8
Connect the CH1 of the Oscilloscope to the Video Output
Connector.
8
Connect the CH2 of the Oscilloscope to the AC Power
Line.
8
Trigger the Oscilloscope at V-rate.
8
Adjust data with the ARROW keys so that the decay point
of V-sync signal gains 2H ± 4H from the zero-cross point
of the AC Power Line Input Waveforms as shown in Fig.
4-1-3.
∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗
M E N U
PANASONIC  EVR  ADJUSTMENT  SYSTEM   (C)MCI  Co.   CCTV  PRODUCT: CS850   EEPROM: 0
<CONTENTS>      TD4 17.73447+–40Hz
<INSTRUCTION> PLEASE  CHOOSE  MENU  DATA  BY  ARROW-KEY
LOAD(F1)
QUIT(F3)
SAVE(F5)
N T S C
1. SC FREQUENCY
2. SC FREQUENCY
3.1. LL PHASE1 FOR AC type (50Hz)
3.2. LL PHASE2 FOR AC type (50Hz)
5. HI CLIP LEVEL
6. PEDESTAL
7. ALC DC
8.1. VIDEO OUT GAIN (L)
8.2. VIDEO OUT GAIN (H)
9.1. BURST LEVEL R
9.2. BURST LEVEL B
9.3. BURST PHASE R
9.4. BURST PHASE B
10.1. WB 3200K MANU OFFSET R
10.2. WB 3200K MANU OFFSET B
11.1. WB 6500K ATW LIMIT R
11.2. WB 6500K ATW LIMIT B
12.1. 3200K R_GAIN
12.2. 3200K B_GAIN
12.3. 3200K R_PHASE
12.4. 3200K B_PHASE
13.1. 5100K R_GAIN
13.2. 5100K B_GAIN
13.3. 5100K R_PHASE
13.4. 5100K B_PHASE
14. HIGHLIGHT CHROMA CLIP
P a g e   ( 1 / 1 )
Main Board
(Digital Section)
TD4
– 2-10 –
Page of 51
Display

Click on the first or last page to see other WV-CS850B / WV-CS854BE service manuals if exist.