Read Panasonic WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 Service Manual Simplified online
15
2.4 WH-SDC09H3E5-1
WH-UD09HE5-1
Item
Unit
Outdoor Unit
Performance Test Condition
EN 14511
Cooling Capacity
Condition
(Ambient/Water)
A35W7
kW 7.00
BTU/h 23900
kcal/h 6020
Cooling EER
W/W 2.43
kcal/hW 2.09
Heating Capacity
Condition
(Ambient/Water)
A7W35 A2W35
kW 9.00
6.70
BTU/h 30700
22800
kcal/h 7740
5760
Heating COP
W/W 4.13
3.13
kcal/hW 3.55
2.69
Heating ErP
Low Temperature Application (W35)
Warmer Average Colder
Application Climate
Pdesign kW
7.0
6.0
7.0
Tbivalent / TOL
°C
2 / 2
-10 / -10
-15 / -22
SCOP / ns
(W/W) / %
5.69 / 225
4.83 / 190
4.08 / 160
Annual Consumption
kWh
1643
2566
4233
Class
A++
A++
A++
Medium Temperature Application (W55)
Warmer Average Colder
Application Climate
Pdesign kW
6.0
7.0
6.0
Tbivalent / TOL
°C
2 / 2
-6 / -10
-15 / -22
SCOP / ns
(W/W) / %
4.07 / 160
3.32 / 130
2.95 / 115
Annual Consumption
kWh
1971
4354
5022
Class
A++
A++
A+
Noise Level
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A)
Cooling: 50
Heating: 51
-
Power Level dB
Cooling: 68
Heating: 69
-
Air Flow
m
3
/min (ft
3
/min)
Cooling: 56.3 (1987)
Heating:51.0 (1800)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S
(900)
Refrigerant (R410A)
kg (oz)
1.45 (51.2)
F-GAS
GWP 2088
CO2eq (ton) (Precharged / Maximum)
3.028 / 4.280
Dimension
Height
mm (inch)
795 (31-5/16)
Width
mm (inch)
900 (35-7/16)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
66 (146)
Pipe Diameter
Liquid
mm (inch)
6.35 (1/4)
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 40 (131)
I/D & O/D Height Difference
m (ft)
30 (98.4)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Click on the first or last page to see other WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 service manuals if exist.