WH-SDC03H3E5-1, WH-SDC05H3E5-1, WH-SDC07H3E5-1, WH-SDC09H3E5-1, WH-UD03HE5-1, WH-UD05HE5-1, WH-UD07HE5-1, WH-UD09HE5-1 - Panasonic Air Conditioner Service Manual Simplified (repair manual). Page 10

Read Panasonic WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 Service Manual Simplified online

10 
Item 
Unit 
Outdoor Unit 
Refrigeration Charge Less 
m (ft) 
10 (32.8) 
Compressor 
Type 
 
Hermetic Motor 
Motor Type 
 
Brushless (4-poles) 
Rated Output 
kW 
0.90 
 Fan 
 Type 
 
Propeller Fan 
 Material 
 
PP 
 Motor Type 
 
DC (8-poles) 
 Input Power 
W 
 Output Power 
W 
40 
 Fan Speed 
rpm 
Cooling: 980 
Heating: 860 
 Heat Exchanger 
 Fin material 
 
Aluminium (Pre Coat) 
 Fin Type 
 Corrugated 
Fin 
 Row × Stage × FPI 
 
2 × 28 × 17 
 Size (W × H × L) 
mm 
36.4 × 588.0 × 827.7 : 856.3 
Power Source (Phase, Voltage, Cycle) 
ø Single 
V 230 
Hz 50 
Input Power 
Condition 
(Ambient/Water)
A35W7 A7W35 A2W35 
kW 
Cooling: 1.67 
Heating: 1.08 
Heating: 1.35 
Maximum Input Power For Heatpump System 
kW 
2.59 
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
1Ø / 12.0 / 2.59k 
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
1Ø / 13.0 / 3.00k 
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
- / - / - 
Starting Current 
5.0 
Running Current 
Condition 
(Ambient/Water)
A35W7 A7W35 A2W35 
Cooling: 7.6 
Heating: 5.0 
Heating: 6.2 
Maximum Current For Heatpump System 
12.0 
Power Factor 
Power factor means total figure of compressor and 
outdoor fan motor. 
Cooling: 96 
Heating: 94 
Heating: 95 
Power Cord 
Number of core 
 
Length m 
(ft) 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127