WH-SDC03H3E5-1, WH-SDC05H3E5-1, WH-SDC07H3E5-1, WH-SDC09H3E5-1, WH-UD03HE5-1, WH-UD05HE5-1, WH-UD07HE5-1, WH-UD09HE5-1 - Panasonic Air Conditioner Service Manual Simplified (repair manual). Page 17

Read Panasonic WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 Service Manual Simplified online

17 
Item 
Unit 
Indoor Unit 
Performance Test Condition 
EN 14511 
Operation Range 
Outdoor Ambient 
°C 
Cooling: 16 ~ 43 
Heating: -20 ~ 35 
Water Outlet 
°C 
Cooling: 5 ~ 20 
Heating: 20 ~ 55 
Internal Pressure Differential 
kPa 
Cooling: 24.0 
Heating: 39.5 
Noise Level 
Condition 
(Ambient/Water)
A35W7 A7W35  A2W35 
dB (A) 
Cooling: 30 
Heating: 30 
Power Level dB 
Cooling: 43 
Heating: 43 
Dimension 
Height 
mm (inch) 
892 (35-1/8) 
Width 
mm (inch) 
500 (19-11/16) 
Depth 
mm (inch) 
340 (13-13/32) 
Net Weight 
kg (lbs) 
44 (97) 
Refrigerant Pipe Diameter 
Liquid 
mm (inch) 
6.35 (1/4) 
Gas 
mm (inch) 
15.88 (5/8) 
Water Pipe Diameter 
Inlet 
mm (inch) 
31.75 (1-1/4) 
Outlet 
mm (inch) 
31.75 (1-1/4) 
Water Drain Hose Inner Diameter 
mm (inch) 
12 (15/32) 
Pump 
Motor Type 
 
DC Motor 
No. of Speed 
 
7 (Software Selection) 
Input Power 
68 
Hot Water Coil 
Type  
Brazed 
Plate 
No. of Plates 
 
48 
Size (W × H × L) 
mm 
82 × 93 × 325 
Water Flow Rate 
l/min (m
3
/h) 
Cooling: 20.1 (1.2) 
Heating: 25.8 (1.5) 
Pressure Relief Valve Water Circuit 
kPa 
Open: 300, Close: 266 and below 
Flow Switch 
 
Electronic Sensor 
Protection Device 
Residual Current Circuit Breaker (30 ~ 40) 
Expansion Vessel 
Volume I 
10 
MWP bar 
Capacity of Integrated Electric Heater 
kW 
3.00 
Note: 
  Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet 
temperature of 12°C and water outlet temperature of 7°C. 
  Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb 
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C. 
  Specification are subjected to change without prior notice for further improvement. 
  Flow rate indicated are based on nominal capacity adjustment of leaving water temperature (LWT) 35°C and  
=5°C 
 
 
 
Page of 127
Display