S-22KA1E5, S-28KA1E5, S-36KA1E5, S-45KA1E5, S-56KA1E5, S-63KA1E5, S-71KA1E5, S-22YA1E5, S-28YA1E5, S-36YA1E5, S-45YA1E5, S-56YA1E5, S-22NA1E5, S-28NA1E5, S-32NA1E5, S-36NA1E5, S-45NA1E5, S-56NA1E5, S-45MA1E5, S-56MA1E5, S-63MA1E5, S-7 - Panasonic Air Conditioner Service Manual (repair manual). Page 5

Read Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual online

WARNING 
WARNING 
CAUTION 
1. Safety Precautions 
x  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
x  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the 
power plug and main circuit for the model installed. 
x  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 
 
This indication shows the possibility of causing death or serious injury 
This indication shows the possibility of causing injury or damage to properties. 
 
x  The items to be followed are classified by the symbols: 
 
 
x  Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 
 
 
1.   Do not modify the machine, part, material during repairing service. 
2.   If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 
3.   Do not wrench the fasten terminal. Pull it out or insert it straightly. 
4.   Engage dealer or specialist with ISO5149 or equivalent requirement for installation and servicing. If installation of servicing done by the user is 
      defective, it will cause water leakage, electrical shock or fire. 
5.   Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire. 
6.   Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire 
      or electrical shock. 
7.   Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done,
      the set will drop and cause injury. 
8.   For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet
      must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
9.   This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD).                      
      Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 
10. Do not use joint cable for indoor / outdoor connection cable. Use the specified indoor / outdoor connection cable, refer to installation instruction 
      CONNECT THE WIRES TO THE CONTROL BOX and connect tightly for indoor / outdoor connection. Clamp the cable so that no external  
      force will be acted on the terminal. If connection or fixing is not perfect, if will cause heat up or fire at the connection. 
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause 
      heat-up or fire at the connection point of terminal, fire or electrical shock. 
12. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle  
       (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.). 
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may  
      climb up to outdoor unit and cross over the handrail and causing accident. 
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and  
      telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown. 
15. When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration cycle.        
     Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in explosion        
     and injury. 
16. Do not damage or use unspecified power supply cord. Otherwise it will cause fire or electric shock. 
17. Do not modify the length of the power supply cord or use extension cord, and do not share the single outlet with other electric appliances.  
     Otherwise, it will cause fire or electric shock. 
18. It is desirable that the amount of residual oil is less than 40 mg/10m. 
 
 
This symbol denotes item that is PROHIBITED from doing. 
Page of 127
Display

Click on the first or last page to see other S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 service manuals if exist.