CW-C180BG, CW-C241SG, CW-A180BG - Panasonic Air Conditioner Service Manual (repair manual). Page 2

Read Panasonic CW-C180BG / CW-C241SG / CW-A180BG Service Manual online

CW-C180BG
– 1 –
 
 
 
 
 
 WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general
public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting
to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians.
Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury
or death.
!
PRODUCT SPECIFICATIONS
MODELS
CW-C180BG
CW-C241SG
CW-A180BG
COOLING
HEATING
CAPACITY
(Btu/h)
17,700
22,510
15, 510
14,830
(W)
5,200
6,600
4,550
4,350
MOISTURE REMOVAL
(
s
/h)
2.9
3.7
2.5
––
(Pints/h)
6.1
7.8
5.3
AIR CIRCULATION
(m
3
/min)
13.7
15.9
13.7
(Cft/min)
480
560
480
COMPRESSOR OUTPUT
(W)
1,700
2,200
1,700
ELECTRICAL
Phase
Single
DATA
Cycle (Hz)
50
Voltage (V)
220
Running
Current (A)
11.2
15.4
11.0
8.9
Starting
Current (A)
50
60
50
Input (W)
2,230
 3,050
2,300
1,700
COP (W/W)
2.33
 2.16
1.98
2.56
CABINET
Height (mm)
16 – 7/8" (428)
16 – 7/8" (428)
16 – 7/8" (428)
DIMENSIONS
Width (mm)
26" (660)
26" (660)
26" (660)
Depth (mm)
25 – 7/32" (640)
28 – 3/4" (730)
25 – 7/32" (640)
NET WEIGHT
(kg)
59
70
59
(Ibs)
130
154
130
REFRIGERANT (R-22)
(g)
980
1,350
1,090
(oz)
34.6
47.7
38.5
NOISE  LEVEL   High
Indoor dB (A)
51
57
51
51
Outdoor dB (A)
59
66
59
60
  Low
Indoor dB (A)
48
53
48
47
Outdoor dB (A)
55
63
56
58
* Specifications are subject to change without notice for further improvement.