CS-VE9NKE, CS-VE12NKE, CU-VE9NKE, CU-VE12NKE - Panasonic Air Conditioner Service Manual (repair manual). Page 9

Read Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual online

Indoor CS-VE12NKE 
Model 
Outdoor CU-VE12NKE 
Type  
Cross-flow 
fan 
Material  
AS+GF 
Resin 
Motor Type 
 
PWM (8-poles) 
Input Power 
28.5 
Output Power 
40 
Cool rpm 
660 
QLo 
Heat
rpm 750 
Cool rpm 
740 
Lo 
Heat
rpm 870 
Cool rpm 
1040 
Me 
Heat
rpm 1050 
Cool rpm 
1190 
Hi 
Heat
rpm 1140 
Cool rpm 
1270 
Indoor Fan 
Speed 
Shi 
Heat
rpm 1140 
Type 
 
Propeller Fan + Flat piece 
Material  
PP 
Motor Type 
 
DC Brushless (8-poles) 
Input Power 
kW 
57.29 
Output Power 
40 
Cool rpm 
960 
Outdoo
r Fa
Speed Hi 
Heat
rpm 
 
Moisture Removal 
L/h (Pt/h) 
2.0 (4.2) 
Cool m
3
/min (ft
3
/m) 4.3 
(152) 
QLo 
Heat m
3
/min (ft
3
/m) 5.4 
(191) 
Cool m
3
/min (ft
3
/m) 5.3 
(187) 
Lo 
Heat m
3
/min (ft
3
/m) 6.9 
(244) 
Cool m
3
/min (ft
3
/m) 9.0 
(318) 
Me 
Heat m
3
/min (ft
3
/m) 9.1 
(321) 
Cool m
3
/min (ft
3
/m) 10.9 
(384) 
Hi 
Heat m
3
/min (ft
3
/m) 10.3 
(362) 
Cool m
3
/min (ft
3
/m) 11.9 
(420) 
Indoor Airflow 
Shi 
Heat m
3
/min (ft
3
/m) 10.3 
(364) 
Cool m
3
/min (ft
3
/m) 
34.2 (1208) 
34.2 (1208) 
Outdoor Airflow 
Hi 
Heat m
3
/min (ft
3
/m) 
31.5 (1112) 
31.5 (1112) 
Control Device 
 
Expansion Valve 
Refrigerant Oil 
cm
3
 FV50S 
(450) 
Refrigeration 
Cycle 
Refrigerant Type
g (oz) 
R410A, 1.50k (52.9) 
Height(I/D / O/D)
mm (inch) 
295 (11-5/8) / 623 (24-1/2) 
Width (I/D / O/D)
mm (inch) 
890 (35) / 799 (31-1/2) 
Dimension 
Depth (I/D / O/D)
mm (inch) 
275 (10-7/8) / 299 (11-3/4) 
Weight 
Net (I/D / O/D) 
kg (lb) 
14.5 (32) / 43 (95) 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different 
m (ft) 
5.0 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Piping 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Page of 127
Display

Click on the first or last page to see other CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE service manuals if exist.