Read Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual online
8
Indoor CS-VE12NKE
Model
Outdoor CU-VE12NKE
Performance Test Condition
EN 14511
Phase, Hz
Single, 50
Power Supply
V 220
230
Min. Mid. Max. Min. Mid. Max.
Capacity
kW
0.60 3.50 4.00 0.60 3.50 4.00
Running Current
A
—
4.1
—
—
3.9
—
Input
Power
W
140 880 1.10k 140 880 1.10k
Annual Consumption
kWh
—
440
—
—
440
—
EER W/W
—
3.98
—
—
3.98
—
Pdsign kW
—
—
—
—
3.50
—
SEER (W/W)
—
—
—
—
8.50
—
Annual Consumption
kWh
—
—
—
—
145
—
Erp
Class
—
—
—
—
A+++
—
Power Factor
%
—
97
—
—
97
—
dB-A
45 / 29 / 26
45 / 29 / 26
Indoor Noise (H / L / QLo)
Power Level dB
60 / -
60 / -
dB-A
50 / -
50 / -
Cooling
Outdoor Noise
(H / L)
Power Level dB
65 / -
65 / -
Capacity
kW
0.60 4.20 8.30 0.60 4.20 8.40
Running Current
A
—
4.0
—
—
3.8
—
Input
Power
W
140 855 3.08k 140 855 3.16k
COP W/W
—
4.91
—
—
4.91
—
Pdsign kW
—
—
—
6.10 / 4.20 / 6.10
Tbivalent °C
—
—
—
2 / -10 / -17
SCOP (W/W)
—
—
—
5.70 / 5.10 / 4.00
Annual Consumption
kWh
—
—
—
1499 / 1153 / 3203
Erp
warm/
ave./
cold
Class
—
—
—
A+++ / A+++ / A+
Power Factor
%
—
97
—
—
97
—
dB-A
45 / 33 / 30
45 / 33 / 30
Indoor Noise (H / L / QLo)
Power Level dB
60 / -
60 / -
dB-A
50 / -
50 / -
Heating
Outdoor Noise
(H / L)
Power Level dB
65 / -
65 / -
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP
—
5.60 / 2.80k / 2.00
Max Current (A) / Max Input Power (W)
15.0 / 3.45k
Starting Current (A)
4.1
3.9
Type
Hermetic
Motor
(Rotary)
Motor Type
Brushless (6-poles)
Compressor
Output Power
W
900
Click on the first or last page to see other CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE service manuals if exist.