2. Specification 
 
Indoor CS-VE9NKE 
Model 
Outdoor CU-VE9NKE 
Performance Test Condition 
EN 14511 
Phase, Hz 
Single, 50 
Power Supply 
V 220 
230 
 
Min. Mid. Max. Min. Mid. Max. 
Capacity 
kW 
0.60 2.50 3.00 0.60 2.50 3.00 
Running Current 
 
2.3 
 
 
2.2 
 
Input 
Power 
140 485 790 140 485 790 
Annual Consumption 
kWh 
 
243 
 
 
243 
 
EER W/W 
 
5.15 
 
 
5.15 
 
Pdsign kW 
 
 
 
 
2.50 
 
SEER (W/W) 
 
 
 
 
8.60 
 
Annual Consumption
kWh 
 
 
 
 
102 
 
Erp 
Class  
 
 
 
 
A+++ 
 
Power Factor 
 
94 
 
 
94 
 
dB-A 
44 / 26 / 23 
44 / 26 / 23 
Indoor Noise (H / L / QLo) 
Power Level dB
59 / - 
59 / - 
dB-A 
49 / - 
49 / - 
Cooling 
Outdoor Noise 
(H / L) 
Power Level dB
64 / - 
64 / - 
Capacity 
kW 
0.60 3.20 7.60 0.60 3.20 7.70 
Running Current 
 
2.8 
 
 
2.7 
 
Input 
Power 
140  585 2.65k 140  585 2.72k 
COP W/W 
 
5.47 
 
 
5.47 
 
Pdsign kW 
 
 
 
5.60 / 3.20 / 4.70 
Tbivalent °C 
 
 
 
2 / -10 / -19 
SCOP (W/W) 
 
 
 
6.00 / 5.40 / 4.10 
Annual Consumption
kWh 
 
 
 
1307 / 830 / 2408 
Erp 
warm/ 
ave./ 
cold 
Class  
 
 
 
A+++ / A+++ / A+ 
Power Factor 
 
94 
 
 
94 
 
dB-A 
44 / 27 / 24 
44 / 27 / 24 
Indoor Noise (H / L / QLo) 
Power Level dB
59 / - 
59 / - 
dB-A 
49 / - 
49 / - 
Heating 
Outdoor Noise 
(H / L) 
Power Level dB
64 / - 
64 / - 
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP 
 
5.00 / 2.37k / 2.11 
Max Current (A) / Max Input Power (W) 
14.0 / 3.22k 
Starting Current (A) 
2.8 
2.7 
Type  
Hermetic 
Motor 
(Rotary) 
Motor Type 
 
Brushless (6-poles)  
Compressor 
Output Power 
900 
Page of 127