7
Indoor CS-VE9NKE
Model
Outdoor CU-VE9NKE
Inner Diameter
mm
16.7
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Indoor Heat
Exchanger
FPI
26.5 + 17
Fin Material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 × 32 × 19.5
Outdoor Heat
Exchanger
Size (W x H x D)
mm
871.6 × 586.24 × 37.8
840.4
840.4
Power Supply
Indoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Control
Protection Device
Electronic Control
DRY BULB
WET BULB
Maximum 32
23
Cooling
Minimum 16
11
Maximum 30
—
Indoor Operation Range
Heating
Minimum 16
—
Maximum 43
26
Cooling
Minimum -10
—
Maximum 24
18
Outdoor Operation Range
Heating
Minimum -20
—
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.