Read Panasonic CS-TZ60TKEW / CS-TZ71TKEW / CU-TZ60TKE / CU-TZ71TKE Service Manual online
14
Model
Indoor CS-TZ71TKEW
Outdoor CU-TZ71TKE
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 15.88 (5/8)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height different
m (ft)
20.0 (65.6)
Additional Gas Amount
g/m (oz/ft)
25 (0.3)
Length for Additional Gas
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
16.7
Length mm
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 17 × 21, Sub EVA: 1 × 4 × 21
Size (W × H × L)
mm
836.5 × 357 × 25.4, Sub EVA: 836.5 × 94.8 × 12.7
Outdoor
Heat
Exchanger
Fin Material
Aluminium
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 31 × 19
Size (W × H × L)
mm
36.4 × 651 × 904.5:874.5
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Outdoor
Power Supply Cord
A
Nil
Thermostat
Electronic
Contol
Protection Device
Electronic Contol
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °C
32
23
Minimum °C
16
11
Heating
Maximum °C
30
–
Minimum °C
16
–
Outdoor
Operation
Range
Cooling
Maximum °C
43
26
Minimum °C
-10
–
Heating
Maximum °C
24
18
Minimum °C
-15
-16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control).
6.
Specifications are subjected to change without prior notice for further improvement.
Click on the first or last page to see other CS-TZ60TKEW / CS-TZ71TKEW / CU-TZ60TKE / CU-TZ71TKE service manuals if exist.