CS-TZ60TKEW, CS-TZ71TKEW, CU-TZ60TKE, CU-TZ71TKE - Panasonic Air Conditioner Service Manual (repair manual). Page 9

Read Panasonic CS-TZ60TKEW / CS-TZ71TKEW / CU-TZ60TKE / CU-TZ71TKE Service Manual online

3. Specifications 
Model 
Indoor CS-TZ60TKEW 
Outdoor CU-TZ60TKE 
Performance Test Condition 
EUROVENT 
Power Supply 
Phase, Hz 
Single, 50 
V 230 
 Min. 
Mid. 
Max. 
Cooling 
Capacity 
kW 
0.98 6.30 7.10 
BTU/h 3340 
21500 
24200 
Kcal/h 840 
5420 
6110 
Running Current 
– 
8.60 
– 
Input Power 
280 
1.93k 
2.38k 
Annual 
Consumption 
kWh 
– 965 – 
EER 
W/W 
3.50 3.26 2.98 
BTU/hW 
11.93 11.14 10.17 
Kcal/hW 
3.00 2.81 2.57 
ErP 
Pdesign kW 
6.3 
SEER (W/W) 
6.5 
Annual 
Consumption 
kWh 339 
Class  
A++ 
Power 
Factor 
– 98 – 
Indoor Noise (H / L / QLo) 
dB-A 
45 / 37 / 34 
Power Level dB 
61 / – / – 
Outdoor Noise (H / L) 
dB-A 
49 / – 
Power Level dB 
64 / – 
Heating
 
Capacity 
kW 
0.98 7.20 8.50 
BTU/h 3340 
24600 
29000 
Kcal/h 840 
6190 
7310 
Running Current 
– 
9.30 
– 
Input Power 
340 
2.09k 
2.70k 
COP 
W/W 
2.88 3.44 3.15 
BTU/hW 9.82 
11.77 
10.74 
Kcal/hW 
2.47 2.96 2.71 
ErP 
Pdesign kW 
4.6 
Tbivalent °C 
-10 
SCOP (W/W) 
4.2 
Annual 
Consumption 
kWh 1533 
Class  
A+ 
Power 
Factor 
– 98 – 
Indoor Noise (H / L / QLo) 
dB-A 
45 / 37 / 34 
Power Level dB 
61 / – / – 
Outdoor Noise (H / L) 
dB-A 
49 / – 
Power Level dB 
64 / – 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
6.16 / 2.39k / 2.58 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
5.24 / 2.40k / 2.18 
Max Current (A) / Max Input Power (W) 
13.1 / 2.70k 
Starting Current (A) 
9.30 
 
Page of 127
Display