CS-TZ60TKEW, CS-TZ71TKEW, CU-TZ60TKE, CU-TZ71TKE - Panasonic Air Conditioner Service Manual (repair manual). Page 18

Read Panasonic CS-TZ60TKEW / CS-TZ71TKEW / CU-TZ60TKE / CU-TZ71TKE Service Manual online

18 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to two separate rooms for CU-2Z35TBE, CU-2Z41TBE, 
CU-2Z50TBE. 
 
CONNECTABLE INDOOR UNIT 
OUTDOOR UNIT 
CU-2Z35TBE CU-2Z41TBE CU-2Z50TBE 
ROOM 
A B A B A B 
Wall
 
1.6kW 
CS-MZ16TKE 
● 
● 
● 
● 
● 
● 
CS-MTZ16TKE 
2.0kW 
CS-Z20TKEW 
● 
● 
● 
● 
● 
● 
CS-XZ20TKEW 
CS-TZ20TKEW 
CS-TE20TKEW 
2.5kW 
CS-Z25TKEW 
● 
● 
● 
● 
● 
● 
CS-XZ25TKEW 
CS-TZ25TKEW 
CS-TE25TKEW 
CS-E9PD3EA 
CS-E9PB4EA 
3.5kW 
CS-Z35TKEW 
● – ● – ● 
● 
CS-XZ35TKEW 
CS-TZ35TKEW 
CS-TE35TKEW 
CS-E12QD3EAW 
CS-E12PB4EA 
4.2kW 
CS-Z42TKEW 
● – ● – ● – 
CS-TZ42TKEW 
CS-TE42TKEW 
5.0kW 
CS-Z50TKEW 
● – ● – ● – 
CS-XZ50TKEW 
CS-TZ50TKEW 
CS-TE50TKEW 
CS-E18RD3EAW 
CS-E18RB4EAW 
Capacity range of connectable indoor units 
3.2kW ~ 6.0kW 
3.2kW ~ 6.0kW 
3.2kW ~ 7.7kW 
Pipe Length
 
1-room maximum pipe length (m) 
20 
20 
20 
Allowable elevation (m) 
10 
10 
10 
Total allowable pipe length (m) 
30 
30 
30 
Total pipe length for maximum  
chargeless length (m) 
20 20 20 
Additional gas amount over  
chargeless length (g/m) 
15 15 15 
 
Note*: Above outdoor unit is contains and operates with refrigerant R32 gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 