Read Panasonic CS-HE9PKD / CS-HE12PKD / CU-HE9PKD / CU-HE12PKD Service Manual online
10
Model
Indoor CS-HE12PKD
Outdoor CU-HE12PKD
Drain Hose
Inner Diameter
mm
16.7
Length mm
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 17 × 21
Size (W × H × L)
mm
636.5 × 357 × 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium (Blue Coated)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 28 × 17
Size (W × H × L)
mm
36.4 × 588 × 606.6
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Indoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °C
32
23
Minimum °C
16
11
Heating
Maximum °C
30
—
Minimum °C
16
—
Outdoor
Operation
Range
Cooling
Maximum °C
43
26
Minimum °C
-15
—
Heating
Maximum °C
24
18
Minimum °C
-15
—
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.