Read Panasonic CS-HE9PKD / CS-HE12PKD / CU-HE9PKD / CU-HE12PKD Service Manual online
8
Model
Indoor CS-HE12PKD
Outdoor CU-HE12PKD
Performance Test Condition
EUROVENT
Power Supply
Phase, Hz
Single, 50
V 220
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.85 3.50 4.00 0.85 3.50 4.00
BTU/h 2900 11900 13600 2900 11900 13600
Kcal/h 730 3010 3440 730 3010 3440
Kcal/h 730 3010 3440 730 3010 3440
Running
Current
A
— 4.1 — — 4.0 —
Input
Power
W
170 870 1.12k 170 870 1.12k
Annual
Consumption kWh — 435 — — 435 —
EER
W/W 5.00 4.02 3.57 5.00 4.02 3.57
BTU/hW 17.06 13.68 12.14 17.06 13.68 12.14
Kcal/hW 4.29 3.46 3.07 4.29 3.46 3.07
Kcal/hW 4.29 3.46 3.07 4.29 3.46 3.07
Power
Factor
% — 96 — — 95 —
Indoor Noise (H / L / QLo)
dB-A
42 / 28 / 20
42 / 28 / 20
Power Level dB
58 / - / -
58 / - / -
Outdoor Noise (H / L / QLo)
dB-A
48 / - / -
48 / - / -
Power Level dB
63 / - / -
63 / - / -
Heating
Capacity
kW 0.85 4.00 6.60 0.85 4.00 6.60
BTU/h 2900 13600 22500 2900 13600 22500
Kcal/h 730 3440 5680 730 3440 5680
Kcal/h 730 3440 5680 730 3440 5680
Running
Current
A
— 4.3 — — 4.2 —
Input
Power
W
165 920 1.82k 165 920 1.82k
COP
W/W 5.15 4.35 3.63 5.15 4.35 3.63
BTU/hW 17.58 14.78 12.36 17.58 14.78 12.36
Kcal/hW 4.42 3.74 3.12 4.42 3.74 3.12
Kcal/hW 4.42 3.74 3.12 4.42 3.74 3.12
Power
Factor
% — 97 — — 95 —
Indoor Noise (H / L / QLo)
dB-A
42 / 33 / 30
42 / 33 / 30
Power Level dB
58 / - / -
58 / - / -
Outdoor Noise (H / L / QLo)
dB-A
60 / - / -
60 / - / -
Power Level dB
65 / - / -
65 / - / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
4.78 / 1.61k / 2.97
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
4.07 / 1.70k / 2.39
Max Current (A) / Max Input Power (W)
8.4 / 1.85k
Starting Current (A)
4.3
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4 poles)
Output Power
W
900