2. Specification
Model
Indoor CS-HE9PKD
Outdoor CU-HE9PKD
Performance Test Condition
EUROVENT
Power Supply
Phase, Hz
Single, 50
V 220
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.85 2.50 3.00 0.85 2.50 3.00
BTU/h 2900 8530 10200 2900 8530 10200
Kcal/h 730 2150 2580 730 2150 2580
Kcal/h 730 2150 2580 730 2150 2580
Running
Current
A
— 2.6 — — 2.5 —
Input
Power
W
170 515 710 170 515 710
Annual
Consumption kWh — 258 — — 258 —
EER
W/W 5.00 4.89 4.23 5.00 4.89 4.23
BTU/hW 17.06 16.56 14.37 17.06 16.56 14.37
Kcal/hW 4.29 4.17 3.63 4.29 4.17 3.63
Kcal/hW 4.29 4.17 3.63 4.29 4.17 3.63
Power
Factor
% — 90 — — 90 —
Indoor Noise (H / L / QLo)
dB-A
39 / 25 / 20
39 / 25 / 20
Power Level dB
55 / - / -
55 / - / -
Outdoor Noise (H / L / QLo)
dB-A
46 / - / -
46 / - / -
Power Level dB
61 / - / -
61 / - / -
Heating
Capacity
kW 0.85 3.40 5.40 0.85 3.40 5.40
BTU/h 2900 11600 18400 2900 11600 18400
Kcal/h 730 2920 4640 730 2920 4640
Kcal/h 730 2920 4640 730 2920 4640
Running
Current
A
— 3.4 — — 3.3 —
Input
Power
W
165 700 1.31k 165 700 1.31k
COP
W/W 5.15 4.86 4.12 5.15 4.86 4.12
BTU/hW 17.58 16.57 14.05 17.58 16.57 14.05
Kcal/hW 4.42 4.17 3.54 4.42 4.17 3.54
Kcal/hW 4.42 4.17 3.54 4.42 4.17 3.54
Power
Factor
% — 94 — — 92 —
Indoor Noise (H / L / QLo)
dB-A
40 / 27 / 24
40 / 27 / 24
Power Level dB
56 / - / -
56 / - / -
Outdoor Noise (H / L / QLo)
dB-A
47 / - / -
47 / - / -
Power Level dB
62 / - / -
62 / - / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
3.91 / 1.16k / 3.37
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
3.33 / 1.29k / 2.58
Max Current (A) / Max Input Power (W)
7.8 / 1.74k
Starting Current (A)
3.4
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4 poles)
Output Power
W
900