CS-HE9PKD, CS-HE12PKD, CU-HE9PKD, CU-HE12PKD - Panasonic Air Conditioner Service Manual (repair manual). Page 7

Read Panasonic CS-HE9PKD / CS-HE12PKD / CU-HE9PKD / CU-HE12PKD Service Manual online

Model 
Indoor CS-HE9PKD 
Outdoor CU-HE9PKD 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length mm 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
2 × 17 × 19 
Size (W × H × L) 
mm 
636.5 × 357 × 25.4 
Outdoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Blue Coated) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 28 × 17 
Size (W × H × L) 
mm 
36.4 × 588 × 606.6 
Air Filter 
Material  
Polypropelene 
Type  
One-touch 
Power Supply 
 
Indoor Power Supply 
Power Supply Cord 
Nil 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
Dry Bulb 
Wet Bulb 
Indoor  
Operation  
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
— 
Minimum °C 
16 
— 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
-15 
— 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-15 
— 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F 
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C. 
5. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 108
Display

Click on the first or last page to see other CS-HE9PKD / CS-HE12PKD / CU-HE9PKD / CU-HE12PKD service manuals if exist.