Read Panasonic CS-E9PD3EA / CS-E12PD3EA / CU-E9PD3EA / CU-E12PD3EA Service Manual online
10
MODEL
INDOOR CS-E12PD3EA
OUTDOOR
CU-E12PD3EA
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
3 x 12 x 18
Size (W x H x L)
mm
620 x 252 x 38.1
Outdoor Heat
Exchanger
Fin Material
Aluminium
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 31 x 17
Size (W x H x L)
mm
36.4 x 651 x 640
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °C
32
23
Minimum °C
16
11
Heating
Maximum °C
30
-
Minimum °C
16
-
Outdoor
Operation
Range
Cooling
Maximum °C
43
26
Minimum °C
-10
-
Heating
Maximum °C
24
18
Minimum °C
-10
-
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3 Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4 Heating extreme low temperature capacity, Input Power and COP measured at 230 V indoor temperature 20°C, outdoor -7/-8°C
5
Standby power consumption ≤0.7W (when switched OFF by remote control, except under self protection control).
6
Specifications are subjected to change without notice for further improvement.