MODEL 
INDOOR CS-E9PD3EA 
OUTDOOR 
CU-E9PD3EA 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard Length 
m (ft) 
5.0 (16.4) 
Length Range (min - max) 
m (ft) 
3 (9.8) ~ 20 (65.6) 
I/D & O/D Height Different 
m (ft) 
15 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
14 
Length mm 
255 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Louver Fin 
Row x Stage x FPI
 
2 x 8 x 20 
Size (W x H x L) 
mm 
620 x 230.2 x 44 
Outdoor Heat 
Exchanger 
Fin Material 
 
Aluminium 
Fin Type 
 
Corrugated Fin 
Row x Stage x FPI
 
2 x 28 x 17 
Size (W x H x L) 
mm 
36.4 x 588 x 606.6 
Power Supply 
 
Outdoor Power Supply 
Power Supply Cord 
Nil 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
Minimum °C 
16 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
-10 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-10 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb 
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3  Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C 
4  Heating extreme low temperature capacity, Input Power and COP measured at 230 V indoor temperature 20°C, outdoor -7/-8°C 
Standby power consumption ≤0.7W (when switched OFF by remote control, except under self protection control). 
Specifications are subjected to change without notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 