Read Panasonic CS-E9PD3EA / CS-E12PD3EA / CU-E9PD3EA / CU-E12PD3EA Service Manual online
8
2.2 CS-E12PD3EA
CU-E12PD3EA
MODEL
INDOOR CS-E12PD3EA
OUTDOOR CU-E12PD3EA
Performance Test Condition
EUROVENT
Power Supply
Phase, Hz
Single, 50
V 220
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW
0.85 3.40 4.00 0.85 3.40 4.00
BTU/h
2900 11600 13600 2900 11600 13600
Kcal/h 730 2920 3440 730 2920 3440
Running
Current
A
- 4.3 - - 4.1 -
Input
Power
W
240 880 1.16k 240 880 1.16k
Annual
Consumption kWh - 440 - - 440 -
EER
W/W 3.54 3.86 3.45 3.54 3.86 3.45
Btu/hW 12.08 13.18 11.72 12.08 13.18 11.72
Kcal/hW 3.04 3.32 2.97 3.04 3.32 2.97
ErP
Pdesign kW
3.4
SEER W/W
5.6
Annual Consumption
kWh
213
Class
A+
Power
Factor
%
- 93 - - 93 -
Indoor Noise (H / L / QLo)
dB-A
33 / 27 / 24
33 / 27 / 24
Power Level dB
49 / - / -
49 / - / -
Outdoor Noise (H / L)
dB-A
46 / - / -
46 / - / -
Power Level dB
61 / - / -
61 / - / -
Heating
Capacity
kW
0.85 4.00 5.10 0.85 4.00 5.10
BTU/h
2900 13600 17400 2900 13600 17400
Kcal/h 730 3440 4390 730 3440 4390
Running
Current
A
- 5.35 - - 5.15 -
Input
Power
W
230 1.13k 1.55k 230 1.13k 1.55k
COP
W/W 3.70 3.54 3.29 3.70 3.54 3.29
Btu/hW 12.61 12.04 11.23 12.61 12.04 11.23
Kcal/hW 3.17 3.04 2.83 3.17 3.04 2.83
ErP
Pdesign kW
2.9
Tbivalent °C
-10
SCOP W/W
3.8
Annual Consumption
kWh
1068
Class
A
Power
Factor
%
- 96 - - 95 -
Indoor Noise (H / L / QLo)
dB-A
35 / 28 / 25
35 / 28 / 25
Power Level dB
51 / - / -
51 / - / -
Outdoor Noise (H / L)
dB-A
47 / - / -
47 / - / -
Power Level dB
62 / - / -
62 / - / -
3 Low Temp. : Capacity (kW) / I. Power (W) / COP
3.70 / 1.37k / 2.70
4 Extr Low Temp. : Capacity (kW) / I. Power (W) / COP
3.00 / 1.27k / 2.36
Max Current (A) / Max Input Power (W)
8.20 / 1.80k
Starting Current (A)
5.35
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4-poles)
Output Power
W
900
Click on the first or last page to see other CS-E9PD3EA / CS-E12PD3EA / CU-E9PD3EA / CU-E12PD3EA service manuals if exist.