Read Panasonic CS-A7HKD / CS-A9HKD / CS-A12HKD / CU-A7HKD / CU-A9HKD / CU-A12HKD Service Manual online
8
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note:
• Specification are subjected to change without prior notice for further improvement.
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugate Fin
Row
× Stage × FPI
2
× 15 × 21
1
× 19 × 17
Size (W
× H × L)
mm (inch)
610
× 315 × 25.4
22
× 483 × 576
Air Filter Type
Material
Polypropelene
—
Style
One-touch
—
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
Single
V 220
230
Hz
50
50
Input power
Cooling
W
830
860
Heating
W
700
740
Starting Current
A
18
18
Running Current
Cooling
A
3.9
3.9
Heating
A
3.3
3.3
Maximum Current
A
5.1
5.1
Power Factor
Cooling
%
97
96
Heating
%
96
97
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.5mm)
Length
m (ft)
2 (6)
Thermostat
—
—
Protection Device
—
2 Stage Overload Protector
Item
Unit
Indoor unit