2 Specifications
2.1.
CS-A7HKD  CU-A7HKD
Item
Unit
Indoor unit
Outdoor unit
Performance Test Condition 
NEW JIS
C
Capacity
kW
2.00 - 2.00
O
BTU/h
6820 - 6820
O
kcal/h
1720 - 1720
L
EER
W/W
3.28 - 3.17
I
BTU/hW
11.2 - 10.8
N
Noise Level
dB (A)
High: 33 Low: 26
High: 46 - 47
G
Power level dB
High: 46
High: 61 - 62
H
Capacity
kW
2.10 - 2.10
E
BTU/h
7160 - 7160
A
kcal/h
1810 - 1810
T
Cop
W/W
4.20 - 4.00
I
BTU/hW
14.3 - 13.6
N
Noise Level
dB (A)
High: 36 Low: 28
High: 48 - 49
G
Power level dB
High: 49
High: 64 - 65
Moisture Removal
l/h
1.3
(pt/h)
2.7
Air Volume
Lo
m
3
/m (ft
3
/m)
Cooling; 5.9 (210)
Heating; 6.3 (220)
Me
m
3
/m (ft
3
/m)
Cooling; 7.0 (250)
Heating; 6.9 (240)
Hi
m
3
/m (ft
3
/m)
Cooling; 7.8 (280)
Heating; 9.0 (320)
Cooling;
29.5 (1040) - 30.0 (1060)
SHi
m
3
/m (ft
3
/m)
Cooling; 9.1 (320)
Refrigerant Control Device
Capillary Tube
Refrigerant Oil (Charged)
cm
3
ATMOS NM56M or
SUNISO 4GDID (290cm
3
)
Refrigerant (Charged) R22
kg (oz)
0.71 (25.0)
Dimension
Height
mm (inch)
280 (11 - 1/32)
510 (20 - 3/32)
Width
mm (inch)
799 (31 - 15/32)
650 (25 - 19/32)
Depth
mm (inch)
183 (7 - 7/32)
230 (9 - 1/16)
Net Weight
kg (lbs)
9 (20)
24 (53)
Pipe Diameter
Gas
mm (inch)
9.52 (3/8”)
Liquid
mm (inch)
6.35 (1/4”)
Height Difference
m (ft)
5 (16.4)
Pipe Length Range
m (ft)
3 (9.8) ~ 10 (32.8)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Refrigeration Charge Less
m (ft)
7.5 (24.6)
Drain Hose
Inner diameter
mm
16
Length
mm
650
Compressor
Type
Rotary (1 cylinder)
rolling piston type
Motor Type
Induction (2-poles)
Rated Output
W
550