CS-A7HKD, CS-A9HKD, CS-A12HKD, CU-A7HKD, CU-A9HKD, CU-A12HKD - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-A7HKD / CS-A9HKD / CS-A12HKD / CU-A7HKD / CU-A9HKD / CU-A12HKD Service Manual online

10
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note:
• Specification are subjected to change without prior notice for further improvement.
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugate Fin
Row 
× Stage × FPI
× 15 × 21
× 24 × 17
Size (W 
× H × L)
mm (inch)
610 
× 315 × 25.4
36.38 
× 504 × 713:684
Air Filter Type
Material
Polypropelene
Style
One-touch
 Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
Single
V 220
230
Hz
50
50
Input power
Cooling
W
1.08
1.12
Heating
W
1.09
1.12
Starting Current
A
20
20
Running Current
Cooling
A
5.1
5.1
Heating
A
5.2
5.1
Maximum Current
A
6.0
6.0
Power Factor
Cooling
%
96
95
Heating
%
95
95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.5mm)
Length
m (ft)
2 (6)
Thermostat
Protection Device
Overload Protector
Item
Unit
Indoor unit
Outdoor unit
Page of 78
Display

Click on the first or last page to see other CS-A7HKD / CS-A9HKD / CS-A12HKD / CU-A7HKD / CU-A9HKD / CU-A12HKD service manuals if exist.