Read JBL VOYAGER (serv.man5) EMC - CB Certificate online
Report No.: SF201300640
Page 58 of 68
National Differences
Clause
Requirement + Test
Result - Remark
Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
5.1.7.1
In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential
bonding has been applied, for example, in a
telecommunication centre; and
bonding has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the
installation of that conductor by a SERVICE
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
N/A
6.1.2.1
(A1:2010)
In Finland, Norway and Sweden, add the
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
-
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
-
two layers of thin sheet material, each of
which shall pass the electric strength test below,
or
-
or
-
one layer having a distance through
insulation of at least 0,4 mm, which shall pass the
electric strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
-
electric strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
-
passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
-
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
-
is subject to ROUTINE TESTING for
electric strength during manufacturing, using a
test voltage of 1,5 kV.
test voltage of 1,5 kV.
No TNV circuits
N/A