Read JBL VOYAGER (serv.man5) EMC - CB Certificate online
Report No.: SF201300640
Page 54 of 68
National Differences
Clause
Requirement + Test
Result - Remark
Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret
og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV
nät kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret
og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV
nät kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
N/A
1.7.5
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK 1-
1b or DK 1-5a.
For
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK 1-
1b or DK 1-5a.
For
CLASS II EQUIPMENT
the socket outlet shall be
in accordance with Standard Sheet DKA 1-4a.
N/A
2.2.4 In
Norway
, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
No TNV circuits within the
equipment
equipment
N/A
2.3.2 In
Finland
, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
6.1.2.1 and 6.1.2.2 of this annex.
No TNV circuits within the
equipment
equipment
N/A
2.3.4 In
Norway
, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
No TNV circuits within the
equipment
equipment
N/A
2.6.3.3 In
the
United Kingdom
, the current rating of the
circuit shall be taken as 13 A, not 16 A.
N/A
Click on the first or last page to see other VOYAGER (serv.man5) service manuals if exist.