Read JBL SPARK (serv.man7) EMC - CB Certificate online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 22 of 48
5. IMMUNITY TEST
5.1 GENERAL DESCRIPTION
Product Standard
ETSI EN 301 489-17 V2.2.1 & EN 301 489-1 V1.9.2
Test set-up
Test specification
ETSI EN 301 489-17
V2.1.1& EN 301
489-1 V1.9.2
V2.1.1& EN 301
489-1 V1.9.2
EN 61000-4-2
Electrostatic Discharge – ESD:
8kV air discharge, 4kV Contact discharge
Performance Criterion B
8kV air discharge, 4kV Contact discharge
Performance Criterion B
EN 61000-4-3
Radio-Frequency Electromagnetic Field
Susceptibility Test – RS:
80 ~1000 MHz, 1400~2700 MHz 3V/m, 80%
AM(1kHz),
Performance Criterion A
Susceptibility Test – RS:
80 ~1000 MHz, 1400~2700 MHz 3V/m, 80%
AM(1kHz),
Performance Criterion A
EN 61000-4-4
Electrical Fast Transient/Burst - EFT,
AC power Port: 1kV,
DC power Port: 0.5kV
Signal and control line: 0.5kV,
Performance Criterion B
AC power Port: 1kV,
DC power Port: 0.5kV
Signal and control line: 0.5kV,
Performance Criterion B
EN 61000-4-5
Surge Immunity Test:
1.2/50 us Open Circuit Voltage,
8 /20 us Short Circuit Current,
AC Power Port: line to earth: ±1kV, line to line:
±0.5kV
Performance Criterion B
1.2/50 us Open Circuit Voltage,
8 /20 us Short Circuit Current,
AC Power Port: line to earth: ±1kV, line to line:
±0.5kV
Performance Criterion B
EN 61000-4-6
Conducted Radio Frequency Disturbances Test
–CS:
0.15 ~ 80 MHz, 3Vrms, 80% AM, 1kHz,
Performance Criterion A
–CS:
0.15 ~ 80 MHz, 3Vrms, 80% AM, 1kHz,
Performance Criterion A
EN 61000-4-11
Voltage dips:
30 during 25 periods,
Meets the requirements of Performance Criterion
Meets the requirements of Performance Criterion
C
100% during 0.5 cycles,
100% during 1 cycles,
100% during 1 cycles,
Meets the requirements of Performance Criterion B
Voltage interruption:
Voltage interruption:
100% during 250 cycles,
Meets the requirements of Performance Criterion C