Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 22 of 48 
 
5. IMMUNITY TEST 
5.1 GENERAL DESCRIPTION 
Product Standard 
ETSI EN 301 489-17 V2.2.1 & EN 301 489-1 V1.9.2 
 
Test set-up 
Test specification 
ETSI EN 301 489-17 
V2.1.1& EN 301 
489-1 V1.9.2 
 
 
EN 61000-4-2 
Electrostatic Discharge – ESD: 
8kV air discharge, 4kV Contact discharge 
Performance Criterion B 
EN 61000-4-3 
Radio-Frequency Electromagnetic Field 
Susceptibility Test – RS: 
80 ~1000 MHz, 1400~2700 MHz 3V/m, 80% 
AM(1kHz),  
Performance Criterion A 
EN 61000-4-4 
Electrical Fast Transient/Burst - EFT, 
AC power Port: 1kV,  
DC power Port: 0.5kV 
Signal and control line: 0.5kV, 
Performance Criterion B 
EN 61000-4-5 
Surge Immunity Test: 
1.2/50 us Open Circuit Voltage, 
8 /20 us Short Circuit Current, 
AC Power Port: line to earth: ±1kV, line to line: 
±0.5kV 
Performance Criterion B 
EN 61000-4-6 
Conducted Radio Frequency Disturbances Test 
–CS: 
0.15 ~ 80 MHz, 3Vrms, 80% AM, 1kHz, 
Performance Criterion A 
EN 61000-4-11 
Voltage dips: 
30 during 25 periods, 
Meets the requirements of  Performance Criterion 
100% during 0.5 cycles, 
100% during 1 cycles, 
Meets the requirements of Performance Criterion B
Voltage interruption: 
100% during 250 cycles, 
Meets the requirements of Performance Criterion C
 
Page of 48