SPARK (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 21

Read JBL SPARK (serv.man7) EMC - CB Certificate online

Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 21 of 48 
 
4.3.4 TEST RESULTS 
Flicker Test Summary per EN/IEC61000-3-3  (Run time) 
 
EUT: JBL 
Tested by: IIANG 
Test Margin: 100 
Test date: 2013-5-2  Start time: 20:10:49  End time: 20:21:10 
Test duration (min): 10 
Data file name: F-000395.cts_data 
Comment: JBL SPARK 
Customer: Customer 
 
Test Result: Pass 
Status: Test Completed 
 
 
Pst
i
 and limit line 
Limits 
0.25
0.50
0.75
1.00
  
Pst
20:21:09
 
Plt and limit line  
0.00
0.25
0.50
  
Plt
20:21:09
 
Parameter values recorded during the test: 
Vrms at the end of test (Volt): 
229.75 
Highest dt (%): 
-0.28  Test limit (%): 3.30  Pass 
Time(mS) > dt:   
0.0 
Test limit (mS): 
500.0  Pass 
Highest dc (%): 
0.00  Test limit (%): 3.30  Pass 
Highest dmax (%): 
0.16  Test limit (%): 4.00  Pass 
Highest Pst (10 min. period):         0.064 
Test limit:                1.000 
Pass    
Highest Plt (2 hr. period):               0.028 
Test limit:                0.650 
Pass 
 
Page of 48