Read JBL SPARK (serv.man7) EMC - CB Certificate online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 21 of 48
4.3.4 TEST RESULTS
Flicker Test Summary per EN/IEC61000-3-3 (Run time)
EUT: JBL
Tested by: IIANG
Test Margin: 100
Test date: 2013-5-2 Start time: 20:10:49 End time: 20:21:10
Test duration (min): 10
Test duration (min): 10
Data file name: F-000395.cts_data
Comment: JBL SPARK
Customer: Customer
Test Result: Pass
Customer: Customer
Test Result: Pass
Status: Test Completed
Pst
i
and limit line
Limits
0.25
0.50
0.75
1.00
Pst
20:21:09
Plt and limit line
0.00
0.25
0.50
Plt
20:21:09
Parameter values recorded during the test:
Vrms at the end of test (Volt):
Vrms at the end of test (Volt):
229.75
Highest dt (%):
-0.28 Test limit (%): 3.30 Pass
Time(mS) > dt:
0.0
Test limit (mS):
500.0 Pass
Highest dc (%):
0.00 Test limit (%): 3.30 Pass
Highest dmax (%):
0.16 Test limit (%): 4.00 Pass
Highest Pst (10 min. period): 0.064
Test limit: 1.000
Pass
Highest Plt (2 hr. period): 0.028
Test limit: 0.650
Pass