SPARK (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 20

Read JBL SPARK (serv.man7) EMC - CB Certificate online

Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 20 of 48 
 
 
4.3 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 
4.3.1 LIMITS 
Test standard: EN 61000-3-3:2008 
Test Item 
Limit 
Remark 
P
st
 1.0 
P
st 
means short-term flicker indicator. 
P
lt
 0.65 
P
lt
 means long-term flicker indicator. 
T
dt
 (ms) 
500 
T
dt 
means maximum time that dt exceeds 3 %. 
d
max
 (%) 
4% 
d
max
 means maximum relative voltage change. 
dc (%) 
3.3% 
dc means relative steady-state voltage change 
4.3.2 TEST PROCEDURES 
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated 
to produce the most unfavorable sequence of voltage changes under normal operating 
conditions. 
During the flick measurement, the measure time shall include that part of whole operation 
cycle in which the EUT produce the most unfavorable sequence of voltage changes. The 
observation period for short-term flicker indicator is 10 minutes and the observation period 
for long-term flicker indicator is 2 hours. 
4.3.3 TEST SETUP 
 
 
Harmonics & 
Flicker 
Analyzer 
Power Source 
 
EUT 
 
Support  
Power 
Cord
 
0.8
Page of 48
Display