SOUNDFLY BT (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate online

 
Page 9 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
The input current is small than 
0.2A. 
 
Constructional requirements with regard to the protection against electric 
shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered. 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
The apparatus was subjected 
of humidity treatment for 168 
hrs at 40
 o
C and R.H. of 95%. 
After the tests, the tests of 10.3 
are made and pass. 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 
N/A 
8.5 
Class I equipment  
See below. 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
Hazardous live parts to 
earthed parts are separated by 
basic insulation. 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
See below. 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Hazardous live parts to 
accessible parts are separated 
by either reinforced or double 
insulation. 
Page of 75
Display

Click on the first or last page to see other SOUNDFLY BT (serv.man3) service manuals if exist.