Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.2
Humidity treatment 48 h or 120 h ........................... :
At 40
o
C, R.H. 95%, 168 hrs.
After the tests, the tests of 10.3
are made and pass.
are made and pass.
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
No electric shock during fault
operation.
(see appended table 11.2)
operation.
(see appended table 11.2)
P
11.2
Heating under fault condition
(see appended table 11.2)
P
Flames extinguish within 10 seconds
No solder became softening
during the tests.
during the tests.
P
No hazard from softening solder
N/A
Soldered terminations not used as protective
mechanism
mechanism
N/A
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table 11.2)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
(see appended table 11.2)
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A