Read JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate online
Page 12 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
See appended table for detail.
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See appended table for detail.
P
c) Discharge not exceeding 45
μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
No access with test finger or
test probe to any parts bearing
hazardous voltage.
test probe to any parts bearing
hazardous voltage.
P
9.1.2
No hazardous live shafts of knobs, handles or levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No hazardous live parts can be
touched by the metal test pin.
touched by the metal test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
The test probe did not become
hazardous live parts after test.
hazardous live parts after test.
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
No access to any parts at
hazardous voltage.
hazardous voltage.
P
9.1.5
Pre‑ set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
The voltage of pins or contacts
for the mains plug no exceed
hazardous live after 2 seconds.
Test voltage: 264V/60Hz,
Measured voltage: 30V.
for the mains plug no exceed
hazardous live after 2 seconds.
Test voltage: 264V/60Hz,
Measured voltage: 30V.
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
See below.
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Hazardous live part is not
accessible.
accessible.
P
b) Test hook of fig. 4 for 10 s (20 N)
Hazardous live part is not
accessible.
accessible.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N force applied. Hazardous
live part is not accessible.
live part is not accessible.
P
9.2
No hazard after removing a cover by hand
N/A
10
Insulation requirements
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ................................................................. :
Surge test with 50 discharges
at a maximum rate of 12/min
from a 1 nF capacitor charged
to 10kV performed. Measured
greater than 4 M
at a maximum rate of 12/min
from a 1 nF capacitor charged
to 10kV performed. Measured
greater than 4 M
Ω between
mains supply terminals to RCA
input terminals.
input terminals.
P
Click on the first or last page to see other SOUNDFLY BT (serv.man3) service manuals if exist.