SB 100 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL SB 100 (serv.man3) EMC - CB Certificate online

Page 14 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.3.2 
General  
T5311: Isolating transformer. 
Pass 
 
Insulation material complies with clause 20.1.4  
See appended table CL. 14. 
Pass 
14.3.3 
Constructional requirements  
See appended table CL. 14. 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
See appended table CL. 13. 
Pass 
14.3.3.2 
Transformers meet the constructional requirements  See appended table CL. 13. 
Pass 
14.3.4 
Separation between windings 
 
Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)..............................: 
See appended table CL. 13. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
See appended table CL. 8.8 & 
8.9. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
 N/A 
14.3.4.3 
Separating transformers with at least basic insulation  
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 Pass 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
See appended table CL.13. 
T5311. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
See appended table CL. 8.8 & 
8.9. 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 N/A 
14.4 
High voltage components  
 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 N/A 
14.5 
Protective devices  
 
Pass 
 
Protective devices used within their ratings  
Primary fuse: F501 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
See appended table CL.13. 
Pass 
Page of 77