Read JBL SB 100 (serv.man3) EMC - CB Certificate online
Page 14 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.2
General
T5311: Isolating transformer.
Pass
Insulation material complies with clause 20.1.4
See appended table CL. 14.
Pass
14.3.3
Constructional requirements
See appended table CL. 14.
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See appended table CL. 13.
Pass
14.3.3.2
Transformers meet the constructional requirements See appended table CL. 13.
Pass
14.3.4
Separation between windings
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
See appended table CL. 13.
Pass
Coil formers and partition walls > 0,4 mm
See appended table CL. 8.8 &
8.9.
8.9.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
Pass
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See appended table CL.13.
T5311.
T5311.
Pass
Coil formers and partition walls > 0,4 mm
See appended table CL. 8.8 &
8.9.
8.9.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Pass
Protective devices used within their ratings
Primary fuse: F501
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
See appended table CL.13.
Pass