SB 100 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL SB 100 (serv.man3) EMC - CB Certificate online

Page 9 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
 N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Primary: Double insulated. 
Pass 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
 N/A 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Primary: Double insulated. 
Pass 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts.
Secondary: Single insulated, 
dressed away from primary. 
N/A 
8.11 
Detaching of wires  
 Pass 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
 
Pass 
 
Vibration test carried out .........................................:   
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 
N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 
Pass 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
No hot parts or sharp edges 
around wires. 
Pass 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
See appended table CL. 14. 
T5311 
Pass 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 
Disconnect device  
Mains plug. 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
 
N/A 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Page of 77
Display