SB 100 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL SB 100 (serv.man3) EMC - CB Certificate online

Page 12 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
12.1.5 
Thermoplastic enclosures stress relief test  
After the test under 70
°C for 7 
hours. 
Enclosure was no damaged. 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers  
 
N/A 
12.3 
Remote controls with hazardous live parts  
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
 
N/A 
12.6 
Telescoping or rod antennas construction  
 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 
N/A 
 
13 
Clearances and creepage distances 
13.1 
Clearances in accordance with 13.3  
See appended table CL. 13. 
Pass 
 
Creepage distances in accordance with 13.4  
See appended table CL. 13. 
Pass 
13.2 
Determination of working voltage  
See appended table CL. 13. 
Pass 
13.3 
Clearances  
See appended table CL. 13. 
Pass 
13.3.1 General 
 
 
Pass 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9.............: 
See appended table CL. 13. 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
 N/A 
13.3.4 Measurement 
of 
transient voltages  
 
N/A 
13.4 
Creepage distances  
See appended table CL. 13. 
Pass 
 
Creepage distances greater than table 11 minimum 
values  
See appended table CL. 13. 
Pass 
13.5 
Printed boards  
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 N/A 
Page of 77