S-5160 - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL S-5160 EMC - CB Certificate online

 
 
page 6 of 49 
Ref.No.:416321  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
8.6 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Between unearthed sec parts 
and hazardous live parts 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Transformers P 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
 N 
8.7 
Basic insulation between parts at 35 V to 71 V (peak) 
a.c. or 60 V to 120 V d.c. and accessible parts 
This clause is not considered 
Noted 
 
Reinforced or double insulation between circuits 
operating at between 35 V and 71 V (peak) a.c. or 
between 60 V and 120 V d.c. and hazardous live 
parts at higher voltage 
 N 
 
Separation by Class 
ΙΙ isolating transformer 
 N 
 
Separation by Class 
Ι transformer 
 N 
 
Separation by earthed conductive part 
 
8.8 
Basic or supplementary insulation 
≥ 0.4 mm (mm) : Plastic insulation sheet behind 
standby PCB and mains 
terminal block: 0.5mm thick 
Main transformers: 
56-0048: One plastic tube (with 
glass fibre on the inside) partly 
applied on each of the basic 
insulated external prim wires to 
the transformer. 
56-0048 and 56-0052: 
Two plastic tubes (with glass 
fibre on the inside) on prim 
lead-in wires passing through 
the sec winding. 
 
Reinforced insulation 
≥ 0.4 mm (mm)  ................... : Standby transformer bobbin 
 
Thin sheet insulation 
In main transformers 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
2 layers of yellow plastic tape  
(+ min 3mm clearance/creepage 
distance in standby transformer) 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 N 
 
Reinforced insulation, two layers each of which 
meet 10.3 
Black plastic tape in main 
transformers (on prim winding 
under prim lead-in wires) 
Page of 56