IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of Table 2 by not
more than 100 K for an area not greater than
2 cm
to 20.1.3, exceeding the limits of Table 2 by not
more than 100 K for an area not greater than
2 cm
2
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm
to 20.1.3 up to 300 K for an area not greater than
2 cm
2
for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of other parts not subject to the
limits of 11.2.1 to 11.2.5
limits of 11.2.1 to 11.2.5
P
12 MECHANICAL
STRENGTH
12.1.1 Bump
test
P
12.1.2
Vibration test
No connection or part which
might impair safety can
become loose.
might impair safety can
become loose.
P
12.1.3 Impact
test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
N
12.5
Antenna coaxial sockets providing isolation
N
13
CLEARANCES AND CREEPAGE DISTANCES
13.1
Clearances and creepage distances in accordance
with 13.2 (fig. 9); minimum distance ..................... :
with 13.2 (fig. 9); minimum distance ..................... :
Prim-sec: 6mm (on control
board, prim wind-C7)
Prim-earthed accessible parts:
3mm (on control board)
board, prim wind-C7)
Prim-earthed accessible parts:
3mm (on control board)
P
13.1.1
Reduction applied if the 3 conditions are met ....... :
N
Reduction applied for Grade 2 winding wire ......... :
N
13.1.2
Use of cemented joints .......................................... :
N
Tests to confirm cemented joints
N
13.2
Clearances and creepage distances of parts of
different polarity connected to the mains, as in
fig. 9; minimum distance ....................................... :
different polarity connected to the mains, as in
fig. 9; minimum distance ....................................... :
3.4mm (on control board)
P