IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Black plastic tape in main
transformers (between prim
solder terminations and sec
winding.
Transparent plastic insulation
in main transformers (between
prim and sec windings)
transformers (between prim
solder terminations and sec
winding.
Transparent plastic insulation
in main transformers (between
prim and sec windings)
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Basic insulated primary wires
can only come into contact
with safety earthed accessible
parts. Other wires are fixed
with cable ties or has insulation
tubings
can only come into contact
with safety earthed accessible
parts. Other wires are fixed
with cable ties or has insulation
tubings
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
No sec wire can come into
contact with live bare parts
contact with live bare parts
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
N
8.11
Detaching of wires
No undue reduction of creepage or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N
Vibration test carried out ....................................... : No, no need.
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (pull test 50 N, for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1.1
Touch current measured from terminal devices
using the network in Annex D ............................... :
using the network in Annex D ............................... :
U1=0.19Vpeak
U2=0.186Vpeak
Between speaker terminals
U
U
oc
= 18Vpeak
P
Discharge not exceeding 45
µC
N
Energy of discharge not exceeding 350 mJ
N
Test with test finger and test probe
P