ON STAGEII (serv.man18) - JBL Audio EMC - CB Certificate (repair manual). Page 40

Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online

 
 
- Page 40 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
before the endurance test in EN 132400, in the 
sequence of tests as described in EN 132400. 
6.1.2.2 
S (FI, NO, SE): The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT
 and
 
PLUGGABLE EQUIPMENT TYPE 
B and equipment 
intended to be used in a 
RESTRICTED ACCESS 
LOCATION
 where equipotential bonding has been 
applied, e.g. in a telecommunication centre, and 
which has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR 
and is provided 
with instructions for the installation of that 
conductor by a service person. 
No TNV circuits. 
N/A 
7.1 
S (FI, NO, SE): Requirements according to this 
annex, 6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK
 in 6.1.2 being 
replaced by the term 
CABLE DISTRIBUTION SYSTEM
Not for connection to cable 
distribution systems. 
N/A 
G.2.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
.
 MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage, and will remain at 230 V in 
case of a single earth fault. 
Not used. 
N/A 
Annex H 
C: Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the 
OPERATOR ACCESS AREA
, the dose rate shall not 
exceed 1 
µSv/h (0,1 mR/h) (see note). Account is 
taken of the background level. 
Replace the notes as follows: 
NOTE  These values appear in Directive 96/29/Euratom. 
 
Delete Note 2. 
The unit does not emit X-ray 
radiation. 
N/A 
Annex H 
A (DE, Regulation on protection against hazards 
by X-ray, of 8
th
 January 1987, Article 5 
[Operation of X-ray emission source], clauses 1 
to 4): 
a) A licence is required by those who operate an 
X-ray emission source. 
b) A licence in accordance with clause 1 is not 
required by those who operate an X-ray emission 
source on which the electron acceleration voltage 
does not exceed 20 kV if 
  1) the local dose rate at a distance of 0,1 m 
from the surface does not exceed 1 µSv/h and 
  2) it is adequately indicated on the X-ray 
emission source that 
  i)  X-rays are generated, and 
  ii)  the electron acceleration voltage must not 
German A deviation withdrawn 
according to Amd. A11:2004. 
N/A 
Page of 77