Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online
- Page 40 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
sequence of tests as described in EN 132400.
6.1.2.2
S (FI, NO, SE): The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT
and
PLUGGABLE EQUIPMENT TYPE
B and equipment
intended to be used in a
RESTRICTED ACCESS
LOCATION
where equipotential bonding has been
applied, e.g. in a telecommunication centre, and
which has provision for a permanently connected
which has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR
and is provided
with instructions for the installation of that
conductor by a service person.
conductor by a service person.
No TNV circuits.
N/A
7.1
S (FI, NO, SE): Requirements according to this
annex, 6.1.2.1 and 6.1.2.2 apply with the term
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK
in 6.1.2 being
replaced by the term
CABLE DISTRIBUTION SYSTEM
.
Not for connection to cable
distribution systems.
distribution systems.
N/A
G.2.1
S (NO): Due to the IT power distribution system
used (see annex V, Fig. V.7), the
used (see annex V, Fig. V.7), the
A
.
C
.
MAINS
SUPPLY
voltage is considered to be equal to the
line-to-line voltage, and will remain at 230 V in
case of a single earth fault.
case of a single earth fault.
Not used.
N/A
Annex H
C: Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA
, the dose rate shall not
exceed 1
µSv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete Note 2.
The unit does not emit X-ray
radiation.
radiation.
N/A
Annex H
A (DE, Regulation on protection against hazards
by X-ray, of 8
by X-ray, of 8
th
January 1987, Article 5
[Operation of X-ray emission source], clauses 1
to 4):
a) A licence is required by those who operate an
X-ray emission source.
b) A licence in accordance with clause 1 is not
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 µSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
to 4):
a) A licence is required by those who operate an
X-ray emission source.
b) A licence in accordance with clause 1 is not
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 µSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
German A deviation withdrawn
according to Amd. A11:2004.
according to Amd. A11:2004.
N/A
Click on the first or last page to see other ON STAGEII (serv.man18) service manuals if exist.